F, r, FE and rE: the letters before the temperatures

F, r, FE and rE are not faults. Each letter names the thermistor whose temperature comes next on the display in Diagnostic Mode. Sub-Zero Pro Repair Denver reads the pairs against each other — (720) 704-2791.

Sub-Zero Pro Repair Denver — (720) 704-2791

Built-In panels read in Diagnostic Mode, older and newer alike

A meter held to a bank of exposed control boards behind the upper grille of a stainless built-in refrigerator

Enter Diagnostic Mode and the panel does not simply list temperatures. It puts a letter up first, then the figure that belongs to it. F is the freezer compartment, r the refrigerator compartment, FE the freezer coil and rE the refrigerator coil.

Read as pairs, they answer what a single figure cannot: is the compartment warm because the coil is warm, or in spite of it.

What we measure

  1. 01 Which letters the cabinet offers at all A combination cabinet lists four. One that only refrigerates lists the refrigerator pair; a freezer lists the freezer pair. The set says what the cabinet is.
  2. 02 Compartment temperature against evaporator temperature, per side The pair is the reading. A compartment sitting warm over a coil that is cold separates an airflow problem from a cooling one.
  3. 03 Whether any letter returns EE instead of a figure That probe is disconnected, shorted or misread. The letter still names it, so the panel tells us exactly which one to test.
  4. 04 The same letters again, after anything has been changed A location code is only worth what the second reading says. Figures that have moved confirm the repair; figures that have not send us back.

What it usually is

A letter with no number beside it that the owner reads as a code

A label doing its job. The letter exists so the next figure has an owner. Nothing about it is a fault.

No band covers this one — quoted after the diagnosis

A compartment reading normally while its evaporator letter reads high

The manual sorts its causes by evaporator temperature for exactly this reason. The coil figure moves first; the shelf follows.

No band covers this one — quoted after the diagnosis

An older cabinet offering a fifth letter the newer ones do not

An inactive line, listed on the earlier generation's table. It is part of how that control describes itself, not a fault it is reporting.

No band covers this one — quoted after the diagnosis

Safe to keep running?

There is nothing here to keep running from. Letters are labels, and a cabinet showing them is simply being read. What matters is the figure each letter introduces: if one of those is wrong, that is where the diagnosis starts.

Bench notes from

Tobias Reinhardt

Trade
Refrigeration technician — doors, gaskets and cabinet fit
Years on the tools
9
Metro
Denver
Holds
EPA 608 certified

Checked against

Sub-Zero Built-In (600-3) service manual #7003192 Rev C, Thermistor Location Code Tables p. 8-5, and 600 Series service manual #3756270 Rev B, p. 8-2

Reading it with you

Tell us what the panel is showing and we will tell you what we would measure first. Sub-Zero Pro Repair Denver — (720) 704-2791. On the road 8:00 am – 8:00 pm, seven days.

Pick a slot on the booking page

An undercounter wine cabinet set into dark walnut, its glass door swung fully open on six empty light-wood bottle shelves above a stainless vent grille

Read the cabinet before anyone quotes it

Describe the symptom on the phone and you will usually hear what it probably is before anyone drives out. A $89 service call covers the visit and the full diagnosis in Denver, and comes off the repair once you approve it.

(720) 704-2791 Book a slot

On the road 8:00 am – 8:00 pm, seven days · the phone never goes quiet